Automatic heating, fine-tuning, securing and marking at temperatures from 50 to 350 °C
- 16 fine calibrators (± 0.5 K) within the rotary indexing system
- Double workpiece carriers with pneumatic locking units
- Calibration of zero and switching point for upper temperature over x/y/z φ – servo axle systems
- Pointer montage, adhering as well as lacquer protection via x/y/s servo axle systems
- High-voltage testing
- Thermal transfer printing with applicator for etiquettes
- Cycle time 18 s including heating and transient oscillation